{"id":482,"date":"2016-04-27T16:34:28","date_gmt":"2016-04-27T15:34:28","guid":{"rendered":"http:\/\/www.crowave.com\/blog\/?p=482"},"modified":"2023-04-11T19:04:46","modified_gmt":"2023-04-11T18:04:46","slug":"reostatski-prenosivi-pult","status":"publish","type":"post","link":"https:\/\/www.crowave.com\/blog\/2016\/04\/27\/reostatski-prenosivi-pult\/","title":{"rendered":"Scheringov mjerni most"},"content":{"rendered":"<p>Danas je nabavljen Scheringov mjerni most u prenosivom drvenom kov\u010degu dimenzija 60x34x16 cm. Jedina oznaka na \u010ditavom ure\u0111aju nalazi se na metalnim bravicama kov\u010dega &#8220;TKG Ljubljana&#8221;. To je oznaka slovenskog poduze\u0107a za proizvodnju vijaka i metalne galanterije (TKG &#8211; Tovarna Kovinske Galanterije) koje je osnovano 1938. godine te je i danas prisutno na tr\u017ei\u0161tu. Vidjeti \u0107emo kasnije da su unutra\u0161njosti ugra\u0111eni Siemensovi kondenzatori sa datumskim oznakama iz 1943. godine te kondenzatori sa logom &#8220;BA 1934&#8221; koji tako\u0111er pripadaju nekom njema\u010dkom proizvo\u0111a\u010du. Sve upu\u0107uje na zaklju\u010dak da je ovaj ure\u0111aj mogao biti izra\u0111en u 1940-tim godinama.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_03.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16520\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_03.jpg\" alt=\"\" width=\"1300\" height=\"794\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_03.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_03-768x469.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_01.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16518\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_01.jpg\" alt=\"\" width=\"1300\" height=\"479\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_01.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_01-768x283.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_02.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16519\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_02.jpg\" alt=\"\" width=\"1300\" height=\"591\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_02.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_02-768x349.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Scheringov most je izmjeni\u010dni mjerni most za mjerenje kapaciteta kondenzatora te kuta gubitaka kondenzatora i dielektri\u010dnih gubitaka izolacije kod razli\u010ditih elektri\u010dnih komponenti i ure\u0111aja pri njihovim radnim naponima.<\/p>\n<p>Idealni kondenzator bi trebao imati samo kapacitivnu komponentu gdje struja prethodi naponu za kut od 90\u00b0. U praksi idealan kondenzator ne postoji i u njemu se dio energije uvijek pretvara u toplinu. Stoga je izmjeni\u010dna struja prema naponu pomaknuta u fazi za kut koji se razlikuje od idealnih 90\u00b0. Veli\u010dina tog pomaka naziva se tangens kuta gubitaka (tg \u03b4) i \u0161to je tg \u03b4 manji to je kondenzator kvalitetniji (sa manjim gubicima).<\/p>\n<p>Kod izolacije pak tg \u03b4 ovisi o veli\u010dini primijenjenog napona, odnosno o jakosti elektri\u010dnog polja kroz izolaciju. Kako se napon pove\u0107ava tako tg \u03b4 polako raste sve do to\u010dke kad izolacija &#8220;probije&#8221; uslijed nastale ionizacije na odre\u0111enoj visina napona. Tu tg \u03b4 naglo poraste i to je krajnja vrijednost napona koju izolacija mo\u017ee izdr\u017eati. Naravno, u praksi se onda odre\u0111uje ni\u017ei pogonski napon za tu izolaciju jer ista ne smije biti izlo\u017eena djelovanju ionizacije. Kod mjerenja gubitaka na izolaciji Scheringov most se napaja izmjeni\u010dnim naponom preko regulacijskog (auto)transformatora kojim se polako podi\u017ee mjerni napon.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_05.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16522\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_05.jpg\" alt=\"\" width=\"1300\" height=\"373\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_05.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_05-768x220.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_04.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16521\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_04.jpg\" alt=\"\" width=\"1300\" height=\"378\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_04.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_04-768x223.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_06.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16523\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_06.jpg\" alt=\"\" width=\"1300\" height=\"764\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_06.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_06-768x451.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Scheringov most se sastoji od R i C elemenata sli\u010dno kao i Wienov most. Wienov most je pogodan za mjerenje kapaciteta i faktora gubitaka izolacijskih materijala kod niskih napona i vi\u0161ih frekvencija, dok je Scheringov most pogodniji za visoke napone i niske frekvencije (mre\u017eni naponi).<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_16.gif\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16533\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_16.gif\" alt=\"\" width=\"1166\" height=\"681\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_16.gif 1166w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_16-768x449.gif 768w\" sizes=\"auto, (max-width: 1166px) 100vw, 1166px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Nacrtali smo elektri\u010dnu shemu na\u0161eg ure\u0111aja. Isti sadr\u017ei samo dvije regulacijske grane mosta \u0161to je i karakteristi\u010dno za prakti\u010dnu izvedbu Scheringovog mosta predvi\u0111enog za visoke radne napone. U tre\u0107oj grani se nalaze \u010disti radni otpornici, a u \u010detvrtoj grani je paralelna kombinacija kondenzatora i otpornika. Za drugu granu mosta je potrebno koristiti vanjski etalonski kondenzator koji ima zanemarivo mali kut gubitaka. Otpornici u tre\u0107oj i \u010detvrtoj grani mosta su odabrani tako da se na njih dijeli mali dio ukupnog napona mosta, tako da se mo\u017ee vr\u0161iti jednostavnije preklapanje \u017eeljenih RC vrijednosti u tim granama. Vidimo da su ti otpornici ispod 1 k\u2126 dok je impedancija u prvoj i drugoj grani na 50 Hz reda M\u2126. Tako ve\u0107ina pada napona nastaje na prvoj i drugoj grani sa mjernim objektom i etalonskim kondenzatorom. Ovo je i jedan od razloga za\u0161to su gornje grane mosta odvojene od donjih grana mosta sadr\u017eanih u na\u0161em ure\u0111aju. Da ne bi do\u0161lo do preskakanja visokog napona, gornje (visokonaponske) grane se oklopljenim kabelima na sigurnoj udaljenosti spajaju sa donjim granama mosta i mjernom granom sa galvanometrom.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_17.gif\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16534\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_17.gif\" alt=\"\" width=\"856\" height=\"592\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_17.gif 856w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_17-768x531.gif 768w\" sizes=\"auto, (max-width: 856px) 100vw, 856px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Ravnote\u017ea mosta, odnosno uga\u0111anje amplitude i faze u na\u0161em slu\u010daju se vr\u0161i se pomo\u0107u promjenjivih RC elemenata (impedancija) u tre\u0107oj i \u010detvrtoj grani mosta. Ako je ispitivani kondenzator (Cx) velikog kapaciteta, onda \u0107e i struja kroz tre\u0107u granu biti velika pa se po potrebi premo\u0161\u0107uje (shuntira) otpornicima na \u010depi\u0161tima 1\/100, 1\/20 i 1\/5. Kada se postigne ravnote\u017ea mosta, onda se prema vrijednostima uklju\u010denih kondenzatora (0,3 \u00b5F ili 3,2 \u00b5F) te prema vrijednostima otpornika i potenciometara u tre\u0107oj i \u010detvrtoj grani mosta mogu izra\u010dunati kapacitivna i radna komponenta kondenzatora, odnosno izra\u010dunati kut gubitaka tg \u03b4. Skale glavnih mjernih potenciometara u \u010detvrtoj grani gravirane su u rasponu 0-1000 \u2126 koliko i iznosi maksimalni otpor istih. Vjerojatno je postojala neka formula sa konstantom na\u0161eg ure\u0111aja preko koje se lako izra\u010dunao tg \u03b4 na osnovu odabranih i o\u010ditanih vrijednosti RC elemenata u donjim granama mosta.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_18.gif\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16535\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_18.gif\" alt=\"\" width=\"230\" height=\"254\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_13.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16530\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_13.jpg\" alt=\"\" width=\"1300\" height=\"509\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_13.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_13-768x301.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><span style=\"color: #00ffff;\"><em>\u017di\u010dani potenciometar od 1 k\u2126 u \u010detvrtoj grani mosta (promjenjivi RC element).<\/em><\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_07.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16524\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_07.jpg\" alt=\"\" width=\"1300\" height=\"521\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_07.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_07-768x308.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><span style=\"color: #00ffff;\"><em>\u017di\u010dani potenciometar od 1 k\u2126 u \u010detvrtoj grani mosta (mjerna grana).<\/em><\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_08.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16525\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_08.jpg\" alt=\"\" width=\"1300\" height=\"580\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_08.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_08-768x343.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><span style=\"color: #00ffff;\"><em>\u017di\u010dani potenciometar od 10 \u2126 u tre\u0107oj grani mosta.<\/em><\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_09.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16526\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_09.jpg\" alt=\"\" width=\"1300\" height=\"623\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_09.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_09-768x368.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><span style=\"color: #00ffff;\"><em>\u017di\u010dani potenciometar od 365 \u2126 u za pode\u0161avanje struje kroz indikacijski instrument.<\/em><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_10.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16527\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_10.jpg\" alt=\"\" width=\"1300\" height=\"648\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_10.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_10-768x383.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_14.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16531\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_14.jpg\" alt=\"\" width=\"1300\" height=\"527\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_14.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_14-768x311.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><em><span style=\"color: #00ffff;\">Fiksni \u017ei\u010dani otpornici u tre\u0107oj grani mosta motani su na poseban na\u010din da se \u0161to vi\u0161e smanji parazitska induktivna i kapacitivna komponenta otpora. \u00a0<\/span><\/em><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_11.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16528\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_11.jpg\" alt=\"\" width=\"1300\" height=\"721\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_11.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_11-768x426.jpg 768w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_11-450x250.jpg 450w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><em><span style=\"color: #00ffff;\">Blokovi paralelno vezanih kondenzatora u \u010detvrtoj grani mosta mogu izdr\u017eati stalan napon do 500 V, no napon napajanja mosta mo\u017ee biti i puno ve\u0107i jer se na tre\u0107u i \u010detvrtu granu mosta raspore\u0111uje samo mali dio napona napajanja.Crnom kondenzatoru u staklenom ku\u0107i\u0161tu koji je vezan u prvom bloku sa jo\u0161 tri kondenzatora nismo mogli pro\u010ditati niti izmjeriti kapacitet (posve je dotrajao, sasu\u0161en i u prekidu). Ovdje zbog starosti ni ostali kondenzatori vi\u0161e nisu sigurni za rad na visokim naponima. \u00a0<\/span><\/em><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_15.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16532\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_15.jpg\" alt=\"\" width=\"1300\" height=\"331\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_15.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_15-768x196.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><span style=\"color: #00ffff;\"><em>Kondenzatori kapaciteta 0,1 \u00b5F su proizvo\u0111a\u010da Siemens vjerojatno iz 1940-tih godina. Kondenzatori kapaciteta 1 \u00b5F imaju \u0161esterokutni logo sa natpisom &#8220;BA 1934&#8221; koji nismo uspjeli povezati sa punim nazivom proizvo\u0111a\u010da.<\/em> <\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_12.jpg\" rel=\"lightbox[482]\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-16529\" src=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_12.jpg\" alt=\"\" width=\"1300\" height=\"827\" srcset=\"http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_12.jpg 1300w, http:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_12-768x489.jpg 768w\" sizes=\"auto, (max-width: 1300px) 100vw, 1300px\" \/><\/a><span style=\"color: #00ffff;\"><em>Dva za\u0161titna iskri\u0161ta od prenapona, jedno sa manjim razmakom koje \u0161titi indikacijski instrument i jedno sa ve\u0107im razmakom za tre\u0107u granu mosta. U tre\u0107oj grani mosta je mogu\u0107a pojava previsokog napona u slu\u010daju da je ispitivani kondenzator velikog kapaciteta ili u kratkom spoju. Tako\u0111er, napon u tre\u0107oj grani mo\u017ee porasti kod proboja izolacije prilikom mjerenja gubitaka na istoj.<\/em><\/span><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p>Elektroni\u010dari se u praksi rijetko susre\u0107u sa Scheringovim mjernim mostom jer je isti predvi\u0111en za visokonaponska mjerenja na energetskim i elektrodistribucijskim postrojenjima, komponentama i ure\u0111ajima. Mogu\u0107e su razne kombinacije otpornih i kapacitivno-otpornih grana Scheringovog mosta, a dana\u0161nji mjerni instrumenti bazirani na tom mostu koriste spojeve sa automatskim uga\u0111anjem ravnote\u017ee mosta \u010dime se odmah dobiva ispis mjerene vrijednosti. Tako\u0111er, postoje posebni spojevi mosta koji mogu mjeriti nepoznati kondenzator i kad mu je jedan kraj uzemljen. Scheringov most mo\u017ee biti potpuno oklopljen kako bi se kompenzirali parazitski kapaciteti izme\u0111u elemenata mosta i uzemljenja. U svakom slu\u010daju Scheringov most je vi\u0161e potreban pogonskim elektri\u010darima i energeti\u010darima, dok je elektroni\u010darima puno bli\u017ei Wienov most koji ima granu sa paralelnim spojem kondenzatora i otpornika, granu sa serijskim spojem kondenzatora i otpornika i dvije grane sa \u010distim radnim otporima. Takav most tako\u0111er mo\u017ee precizno mjeriti kapacitet i kut gubitaka kondenzatora i to na visokim frekvencijama, a osim toga sa istim se mogu izra\u0111ivati i vrlo lijepi sinusni oscilatori u \u0161irokom rasponu frekvencija \ud83d\ude42<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Danas je nabavljen Scheringov mjerni most u prenosivom drvenom kov\u010degu dimenzija 60x34x16 cm. Jedina oznaka na \u010ditavom ure\u0111aju nalazi se na metalnim bravicama kov\u010dega &#8220;TKG Ljubljana&#8221;. To je oznaka slovenskog poduze\u0107a za proizvodnju vijaka i metalne galanterije (TKG &#8211; Tovarna Kovinske Galanterije) koje je osnovano 1938. godine te je i danas prisutno na tr\u017ei\u0161tu. Vidjeti [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":16520,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[15],"tags":[28],"class_list":{"0":"post-482","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mjerni","8":"tag-reostatski-prenosivi-pult","9":"czr-hentry"},"jetpack_featured_media_url":"https:\/\/crowave.com\/blog\/wp-content\/uploads\/2016\/04\/schering_most_03.jpg","_links":{"self":[{"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/posts\/482","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/comments?post=482"}],"version-history":[{"count":6,"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/posts\/482\/revisions"}],"predecessor-version":[{"id":16536,"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/posts\/482\/revisions\/16536"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/media\/16520"}],"wp:attachment":[{"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/media?parent=482"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/categories?post=482"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.crowave.com\/blog\/wp-json\/wp\/v2\/tags?post=482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}